The Research Article on Stability Indicating RP-HPLC Method Development and Validation for Simultaneous Estimation of Ticagrelor and Aspirin in Synthetic Mixture

 

Avani N. Doshi1*, Vidhi Kotadiya2, Isha R. Mishra3

1HOD & Professor of Pharmaceutical QA/Chemistry, K. B. Raval College of Pharmacy,

Gandhinagar, Gujarat, India. ORCIDs: 0000-0002-9959-2039

2Associate Professor of Pharmaceutical QA/Chemistry K. B. Raval College of Pharmacy,

Gandhinagar, Gujarat, India. ORCIDs: 0009-0005-5098-3433

3Research Scholar, K. B. Raval College of Pharmacy, Gandhinagar, Gujarat, India.

*Corresponding Author E-mail: avanidoshi20211@gmail.com

 

ABSTRACT:

A simple, rapid, economical, precise, and accurate stability-indicating RP-HPLC method for estimating ticagrelor and Aspirin in a synthetic mixture has been developed. A reverse phase high-performance liquid chromatographic method was developed for the estimation of Ticagrelor and Aspirin in a synthetic mixture has been developed. The separation was achieved using Waters Symmetry C18 (150mm × 4.6mm × 5μ), Phosphate buffer (pH 7.5) and methanol as mobile phase, at a flow rate of 1.0ml/min. Detection was carried out at 215nm, and retention times of Ticagrelor and Aspirin were found to be 3.853 and 6.829min. The method has been validated for linearity, accuracy, and precision. Linearity observed for Ticagrelor and Aspirin 45 – 135 μg/ml. The developed method was found to be accurate, precise, and rapid for estimating ticagrelor and Aspirin in a synthetic mixture. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis, and Thermal degradation under the same chromatographic conditions. The stress samples were assayed on RP-HPLC system.

 

KEYWORDS: Ticagrelor, Aspirin, Stability indicating RP- HPLC Method, Validation.

 

 


1: INTRODUCTION1

Heart Attack: A heart attack occurs when an artery that sends blood and oxygen to the heart is blocked. Fatty, cholesterol-containing deposits build up over time, forming plaques in the heart's arteries. If a plaque ruptures, a blood clot can form. The clot can block arteries, causing a heart attack. During a heart attack, a lack of blood flow causes the tissue in the heart muscle to die.

 

Ticagrelor and Aspirin are used to prevent a Heart Attack. Ticagrelor is an antiplatelet medication, while Aspirin is a non-steroidal anti-inflammatory drug (NSAID) with antiplatelet action. Together, they work by preventing platelets from sticking together, which decreases the formation of harmful blood clots. This lowers the chance of a heart attack or stroke.


2: DRUG INTRODUCTION 1-5

Table 1: Drug profile of Ticagrelor

Property

Information

Drug Name

Ticagrelor

Chemical Formula

C23H28F2N6O4S

Chemical Structure

IUPAC

(1S,2S,3R,5S)-3-(7-{[(1R,2S)-2-(3,4-difluorophenyl)cyclopropyl]amino}-5-(propylsulfanyl)-3H-[1,2,3]triazolo[4,5-d]pyrimidin-3-yl)-5-(2-hydroxyethoxy)cyclopentane-1,2-diol

CAS No.

274693-27-5

Melting Point

138 °C -140 °C

Solubility

Soluble in ethyl acetate, Solubility in water

LogP

2.31

pKa (Strongest acidic)

12.94

pKa (Strongest basic)

1.11

Pharmacological Class

Ticagrelor is a P2Y12 receptor antagonist

Mechanism of Action

Ticagrelor is a P2Y12 receptor antagonist. The P2Y12 receptor interacts with Gαi2 and other Gi proteins, inhibiting adenylyl cyclase. Gi-mediated signaling also activates the PI3K, Akt, Rap1b, and potassium channels. The downstream effects of these activities mediate haemostasis and cause platelet aggregation. Antagonism of the P2Y12 receptor lowers the formation of occlusive thromboses, which may lower the risk of myocardial infarction and ischemic stroke.

Route of Administration

Oral

Dosage Form

Tablets

Approval Date

Ticagrelor was patented in 2001. It was approved in the US

Side Effects

Shortness of breath, Irregular breathing, headache, nausea or vomiting, discomfort.

 

Table 2: Drug profile of Aspirin

Property

Information

Drug Name

Aspirin

Chemical Formula

C9H8O4

Chemical Structure

IUPAC

2-(acetyloxy)benzoic acid

CAS No.

50-78-2

Melting Point

138-140

Solubility

Slightly soluble in water

LogP

1.18

pKa (Strongest acidic)

3.41

pKa (Strongest basic)

-7.1

Pharmacological Class

Antithrombotic agents: platelet aggregation inhibitors excl. Heparin

Mechanism of Action

Acetylsalicylic acid (ASA) inhibits prostaglandin production. It is not specific for COX-1 or COX-2 enzymes. Inhibition of COX-1 inhibits platelet aggregation for around 7-10 days. The acetyl group of acetylsalicylic acid binds to a serine residue on the cyclooxygenase-1 (COX-1) enzyme, causing irreversible inhibition. This inhibits the formation of pain-causing prostaglandins. This process also inhibits the conversion of arachidonic acid to thromboxane A2(TXA2), a powerful inducer of platelet aggregation. Platelet aggregation can cause clots and dangerous venous and arterial thromboembolism, resulting in illnesses including pulmonary embolism and stroke.

Route of Administration

Oral

Dosage Form

Tablets

Approval Date

Aspirin was approved for medical use in 1999 in US.

Side Effects

Stomach or gut irritation, constipation, nausea, sleepiness, vomiting, headache, dizziness.

 

3: LITERATURE REVIEW6-26

Table 3: Published Analytical methods of Ticagrelor

Sr. No.

Title

Method Parameters

Ref

1.

RP-HPLC Method For Ticagrelor

Column: C18 (250 × 4.6mm, 5µm)

Mobile phase: Acetonitrile and Methanol in the ratio of 70: 30% v/v

Flow rate: 1ml/min

Detection: 254nm

Retention time: 3.793 min.

9

2.

Bioanalytical Method Development and Validation of Ticagrelor By RP-HPLC

Column: C18 (250 × 4.6mm, 5µm)

Mobile phase: Acetonitrile and Methanol in the ratio of 60:40% v/v

Flow rate: 1ml/min

Retention time:4.503 min

For UV

Wavelength: 254

10

3.

RP-HPLC of Ticagrelor Tablets

Column: C18 column (Kromasil, 250×4.6 mm, 5 µ)

Mobile phase: aqueous buffer (containing 0.5 ml formic acid and triethylamine each in water) and acetonitrile in the ratio of 50:50 v/v

Flow rate: 1.3ml/min

Detection:  256nm

Retention time: 3.372 min

11

4.

RP- HPLC Method for the Estimation of Ticagrelor in Formulation

Column: C18G (250× 4.6mm)

Mobile phase: methanol and water in the ratio of 20:80 v/v

Flow rate: 1.0ml/min

Detection: 254nm

Retention times: 5.786min

12

5.

Validated RP-HPLC Method for the estimation of Ticagrelor in Bulk and Pharmaceutical Dosage Forms

Column: C18 column (250mm×4.6 mm, 5μm particle size)

Mobile phase: Methanol: Phosphate buffer (PH adjusted to 4 with orthophosphoric acid) (75: 25% v/v)

Flow rate: 1ml/min

Detection:  256nm

Retention time:  2.750min.

13

6.

RP-HPLC Method for the Determination of Ticagrelor (an antiplatelet agent) in Pharmaceutical Dosage Form

Column: C18 column (of 4.6 mm i.e. X 250 mm, 5µm particle size)

Mobile phase: Acetonitrile: Methanol (50:50 % v\v)

Flow rate: 1ml/min

Detection: 255nm

Retention time: 2.997min.

14

7.

Determination of the New Antiplatelet Agent Ticagrelor in Tablets by Stability-Indicating HPLC Method

Column: C18 column (250 x 4.6 mm, 5μm)

Mobile phase: Acetonitrile: water with 0.5% triethylamine (57:43 v/v)

Flow rate: 0.7ml/min

15

8.

UV and HPLC method for quantification of ticagrelor in bulk and tablet dosage form

Column: Phenomenex C18 column (250mm x 4.6mm, 5μm particle size)

Mobile phase: 30:70 % v/v of acetonitrile: glacial acetic acid 1 %

Retention time: 3.910 min

Detection: 306 nm

16

9.

Bioanalytical RP-HPLC method for simultaneous quantification of rivaroxaban and ticagrelor

Column: C18 (250×4.6mm; 5μm)

Mobile phase: acetonitrile and 0.1% orthophosphoric acid buffer in a 40:60 v/v

Flow rate: 1.0ml/min

Detection: 265 nm

Retention time: 4.716min, 6.396min and 5.405 min

17

 

Table 4: Published Analytical methods of Aspirin

Sr. No.

Title

Method Parameters

Ref

1.

RP-HPLC method of omeprazole and aspirin in the presence of salicylic acid as a degradation product

Column: Symmetry C18 (150 × 4.6 mm, 5 µm) hermo Scientific Hypersil ODS column (250 × 4.6 mm, 5 µm) column

Mobile phase: composed of acetonitrile: 0.05 M sodium phosphate monobasic buffer with 0.1% TEA (23:77, v/v)

Flow rate: 1.2 ml/min

Detection: 284 nm

Retention time: 4.77 ± 0.23min.

18

2.

RP-HPLC method for Aspirin and Clopidogrel

Column: A Phenomenex Gemini C-18, 5 µm column having 250mm x 4.6 mm

Mobile phase: Buffer solution 0.3% orthophosphoric acid: acetonitrile (65: 35% v/v)

Flow rate: 1.0 ml/min

Detection: 266 nm

19

3.

RP-HPLC of aspirin, rosuvastatin, clopidogrel

Column: Biscof HPLC C18 column (250 mm × 4.6 mm, 5nm

Mobile phase: Of Aspirin, Rosuvastatin, Clopidogrel

Flow rate: 1.0 ml/min

Detection: 237 nm

20

4.

Stability indicating RP-HPLC method for Simultaneous Estimation of Ramipril, Aspirin and Simvastatin

Column: C18, 250×4.6mm, 5 micron size c

Mobile phase: consisting of 0.5% Ortho phosphoric acid: ACN: Methanol (20:10:70% v/v/v)

Flow rate: 0.8 ml/min

Detection: 260 nm

Retention time: 2.88 min.

21

5.

Stability indicating Spectrofluorimetric and RP-HPLC method for Determination of Aspirin and Dipyridamole in their Combination

Column: C8, 10 m, 250mmx4.6mm

Mobile phase: water-acetonitrile-ortho-phosphoric acid (65:35:2 %v/v/v)

Flow rate: 1.5 ml/min

Detection: 250 nm

Retention time: 2.2, 3.8 & 4.6 min.

22

6.

RP-HPLC method for of Aspirin and Atorvastatin Singly and in Combination

Column: Phenomenex Luna analytical column, 150 mm × 4.6 mm, 5μm

Mobile phase: 0.1% glacial acetic acid in water and acetonitrile in the ratio of 50:50 % v/v

Flow rate: 1.0 ml/min

Detection: 246 nm

23

7.

Stability-indicating HPLC Method for Simultaneous Determination of Aspirin and Prasugrel

Column: Kromasil 100 C18 (150×4.6 mm, 5μ)

Mobile phase: A: Acetonitrile: Methanol composed of acetonitrile: methanol: water (30:10:60 %v/v/v),

Retention times: 3.28 min and 6.61 min

24

8.

Stability indicating RP-HPLC method for aspirin and prasugrel in combination capsule dosage

Column: waters symmetry C18 (250mm, 4.6mm, 5μm)

Mobile phase: 0.1M of potassium dihydrogen phosphate buffer (pH 3.2) and methanol in the proportion of 65: 35 % (v/v) and photodiode array detection at 220nm.

25

9.

Stability-Indicating RP-HPLC Of Ramipril, Atorvastatin Calcium and Aspirin in a Combined Capsule Dosage Form

Column: C18 Grace column

Mobile phase: methanol: potassium dihydrogen phosphate buffer

10mM adjusted to pH 3 (70:30 % v/v)

Flow rate: 0.9 ml/min

Detection: 215 nm

Retention time:  3.751min.

26

 

5: METHOD DEVELOPMENT:

Wavelength selection:

 

Figure 1: UV Spectra of Ticagrelor and Aspirin for Wavelength selection

 


Observation:

Ticagrelor and Aspirin both drugs give significance absorbance at 215nm.  So 215nm has been selected as detection wavelength.

 

FINAL CHROMATOGRAPHY METHOD:

Table 5: Optimized Chrmoatographic Condition for Ticagrelor and Aspirin by RP-HPLC

Parameters

Particulars

Mobile phase

Phosphate buffer pH 7.5: Methanol (30:70%v/v)

Stationary phase

Water C18 (150mm x 4.6mm x 5µ)

Flow rate

1.0mL/min

Wavelength

215nm

Injection volume

5µL

Column Temperature

25°C

Run time

10 minutes

6. METHOD VALIDATION:5, 27, 28

Observation:

The areas obtained were directly proportional to the concentration of analyte in the sample. The method can, therefore, be termed as linear in the specified range.

 

Linearity:

Linearity of the method was established by preparing standard solutions at five different concentration levels covering the range of 37.50 – 112.5µg/mL   for Aspirin and 45 – 135µg/mL L for Ticagrelor. Each concentration was injected in triplicate, and calibration curves were plotted between concentration and peak area.

 


 

 

Figure 2: Overlaying linearity chromatogram of Ticagrelor and Aspirin

 


The regression analysis showed a linear relationship with correlation coefficient (r2) values greater than 0.999 for all three drugs, indicating excellent linearity within the selected range. Result of regression Analysis mentioned a Table no. 6.

 

Table 6: Regression Data obtained from calibration curve of Aspirin and Ticagrelor

Parameter

Aspirin

Ticagrelor

Range (µg/mL)

37.50 – 112.5

45 - 135

Slope

6932.4

91653

Intercept

50505

1280.9

R2

0.9991

0.9981

 

Precision:

Precision tested at intra-day and inter-day levels (n = 6 samples). Results are summarized below respectively

 

Table 7: Inter-day precision results of Ticagrelor

Inter-day precision

50.00%

100.00%

150.00%

Day-1

862810

1995737

2667842

Day-2

861694

1950553

2658648

Day-3

857379

1965563

2672042

Average

860627.6667

1970618

2666177

% RSD

0.33

1.17

0.26

 

Table 8: Inter-day precision results of Aspirin

 

Inter-day precision

 

50.00%

100.00%

150.00%

Day-1

939238

1844902

2731395

Day-2

930505

1815614

2703853

Day-3

918234

1813084

2690208

Average

929325.6667

1824533

2708485

% RSD

1.14

0.97

0.77

 

Acceptance limits:

%RSD of the assay should be less than 2.

 

Conclusion:

%RSD of the assay n=6 was found to be less than 2 in all the results. Therefore, method is precise.

 

Accuracy:

The proposed method when used for evaluation of recovery at three concentration levels, 50%, 100%, and 150% after spiking with standard, showed % recovery between 98% – 102% for both drugs.

 

Table 9: Recovery data for Ticagrelor                                 (n =3)

Sr. No

Conc.

Levels %

Amount

Added

Amount

recovered

% Recovery

% Mean

Recovery

% RSD

1.

50%

0.450

0.445

98.9

98.9

0.5

2.

0.450

0.443

98.4

3.

0.450

0.447

99.4

4.

100%

0.900

0.886

98.4

98.2

0.3

5.

0.900

0.880

97.8

6.

0.900

0.884

98.3

7.

150%

1.350

1.338

99.1

98.6

0.7

8.

1.350

1.320

97.8

9.

1.350

1.337

99.0

 

Table 10: Recovery data for Aspirin                                    (n =3)

Sr. No

Conc.

Levels %

Amount

Added

Amount

recovered

% Recovery

% Mean

Recovery

% RSD

1.

50%

0.375

0.373

99.5

98.8

0.8

2.

0.375

0.372

99.1

3.

0.375

0.367

97.9

4.

100%

0.750

0.735

98.0

98.0

0.7

5.

0.750

0.730

97.3

6.

0.750

0.740

98.7

7.

150%

1.125

1.146

101.8

101.0

0.7

8.

1.125

1.130

100.4

9.

1.125

1.136

100.9

 

Observation:

The result of this study was found to be within the acceptance criteria of method validation this proves that the test method is accurate for the estimation of Ticagrelor and Aspirin synthetic mixture.

 

Robustness:

Deliberate change in different parameters was found to be within the acceptance limit. The %RSD should be less than 2%, indicating that the method was robust.


 

Table 11: Forced degradation percentage of Aspirin by RP-HPLC

Degradation Condition

Area of treated sample

% Degradation

Area of treated standard

% Degradation

Acid (1 N HCl  4 hours)

1712726

9.1

1684157

6.0

Base (1 N NaOH  4 hours)

1803858

4.3

1677114

6.4

Peroxide (0.3% H2O2, RT)

1719294

8.8

1787771

0.3

Thermal (70 °C, 12 hrs)

1855481

1.6

1630124

9.1

Photo (sunlight for 2 days)

1626914

13.7

1743444

2.7

 

Table 12: Forced degradation percentage of Ticagrelor by RP-HPLC

Degradation Condition

Area of treated sample

% Degradation

Area of treated standard

% Degradation

Acid (1 N HCl  4 hours)

1307185

30.7

1290311

28.0

Base (1 N NaOH  4 hours)

1672788

11.3

1710360

4.6

Peroxide (0.3% H2O2, RT)

1837616

2.5

1690335

5.7

Thermal (70°C, 12 hrs)

1881201

0.2

1593101

11.1

Photo (sunlight for 2 days)

1810985

3.9

1750307

2.4

 


Figure 3: Chromatogram of Standard Aspirin (75µg/mL) and Ticagerol (90µg/mL)

 

Specificity:

The assessment of specificity involved comparing chromatograms of the mobile phase blank, placebo solution, standard solution, and sample solution. In this evaluation, separate injections of 20 μl from the mobile phase blank, standard solution, and sample solution were introduced into the HPLC system.

 

RESULTS:

The present study focused on the development and validation of a stability-indicating RP-HPLC method for the simultaneous estimation of Ticagrelor and Aspirin in a synthetic mixture. The method was successfully optimized using a suitable mobile phase and detection wavelength, achieving adequate resolution between the two drugs and their respective degradation products.

 

The retention times of Ticagrelor and Aspirin were well separated, with sharp and symmetrical peaks indicating the method's specificity. Linearity was established over an appropriate concentration range for both drugs, showing high correlation coefficients (r˛ > 0.999). The method demonstrated good accuracy, with percent recovery within acceptable limits, and precision was confirmed through low %RSD values in both intra-day and inter-day studies.

 

Forced degradation studies under various stress conditions (acidic, basic, oxidative, thermal, and photolytic) confirmed the stability-indicating nature of the method, as the drugs could be effectively quantified even in the presence of their degradation products.

 

Furthermore, the method was found to be robust and rugged, as minor changes in chromatographic conditions did not significantly affect the results.

 

These results support the applicability of the developed RP-HPLC method for routine analysis of Ticagrelor and Aspirin in pharmaceutical dosage forms, ensuring quality control and stability monitoring.

 

CONCLUSION:

A stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method was successfully developed and validated for the simultaneous estimation of Ticagrelor and Aspirin in a synthetic mixture. The method demonstrated good sensitivity, accuracy, precision, and robustness as per ICH guidelines. It effectively separated the drugs from their degradation products, confirming its stability-indicating nature. This validated method can be reliably employed for routine quality control and stability testing of Ticagrelor and Aspirin in pharmaceutical formulations, ensuring the safety, efficacy, and quality of the combination product throughout its shelf life.

 

REFERENCES:

1.      Drug Bank/Ticagrelor, November 24, 2024, https://go.drugbank.com/drugs/DB06624

2.      PubChem Ticagrelor, October 2021, https://pubmed.ncbi.nlm.nih.gov/35396017/

3.      Drug Bank/Aspirin https://go.drugbank.com/drugs/DB00945

4.      PubChem/Aspirin, https://pubchem.ncbi.nlm.nih.gov/compound/ Aspirin

5.      International Conference on Harmonization, ICH guidelines Q1A (R2). Stability Testing of New Drug Substances and Products

6.      Carr, G. P., and Wahlich, J. C. A practical approach to method validation in pharmaceutical analysis. Journal of Pharmaceutical and Biomedical Analysis. 1990; 8(12): 613-618.

7.      IPC/GD/04, Indian Pharmacopoeia Commission, Ministry of Health & Family Welfare, Government of India, 16th September 2021

8.      International conference on harmonization, ICH harmonised tripartite guideline stability testing of new drug substances and products Q1A(R2) current step 4 version dated 6 february 2003.

9.      ICH harmonised tripartite guideline impurities in new drug substances Q3A(R2) current step 4 version dated 25 october 2006

10.   International Conference on Harmonization, ICH Q2R2, Validation of Analytical Procedures, Text and Methodology

11.   Joshy E, Babu A, D’Cruz D, TP A. Development and validation of RP-HPLC method for determination of ticagrelor in pharmaceutical dosage formulation. Der Pharmacia Lettre. 2016; 8(9): 206–212.

12.   D’Cruz D, Babu A, Joshy E, T P A. Bioanalytical method development and validation of ticagrelor by RP-HPLC. Int J Appl Pharm. 2017; 9(3): 51–4

13.   Tabassum K, Sarvesh R. Analytical method development and validation studies of ticagrelor tablets by RP-HPLC. Int J Appl Pharm. 2017; 9(4): 10–21.

14.   Shyamalambica P, Vijaya Lakshmi M. Development and validation of stability indicating RP-HPLC method for the estimation of ticagrelor in formulation. Int J Eng Res Technol. 2018; 7(10): 81.

15.   Ravisankar P, Prasada Rao CV, Gunturu SK, Srinivasa Babu P, Navya P, Nayak MT. Development and validation of RP-HPLC method for the determination of ticagrelor (an antiplatelet agent) in pharmaceutical dosage form. July 2021

16.   Parida AK, Rao KS, Patnaik AK. A novel validated RP-HPLC method for the estimation of ticagrelor in bulk and pharmaceutical dosage forms. Res J Pharm Technol. 2018; 11(3): 1019-1024.

17.   Gobetti C, Lazzaretti Pereira R, Loureiro Mendez AS, Garcia CV. Determination of the new antiplatelet agent ticagrelor in tablets by stability-indicating HPLC method. Curr Pharm Anal. 2014; 10(4): 279-83.

18.   Bairam R, Tatapudi HK, Gajji N, Rasheed SH. UV spectrophotometric and HPLC method for quantification of ticagrelor in bulk and tablet dosage form. Asian J Pharm Anal. 2022; 12(3): 159-65.

19.   Eswarudu MM, Rao AL, Vijay K. Bioanalytical RP-HPLC method for simultaneous quantification of rivaroxaban and ticagrelor in spiked human plasma: Validation and stability. Res J Pharm Technol. 2023; 16(6): 2741-6.

20.   Kamal AH, Marie AA, Hammad SF. Stability indicating RP-HPLC method for simultaneous determination of omeprazole and aspirin in the presence of salicylic acid as degradation product. Microchem J. 2020; 152: 104350.

21.   Gousuddin M, Sengupta P, Tripathi VD, Das A. Stability indicating RP-HPLC method for simultaneous determination of aspirin and clopidogrel in dosage form. Malays J Anal Sci. 2016; 20(2): 247–57.

22.   Pisal P, Nigade GA, Kale AM, Pawar SM. Development and validation of stability indicating RP-HPLC method for simultaneous determination of aspirin, rosuvastatin, clopidogrel in bulk and pharmaceutical dosage form. Int J Pharm Pharm Sci. 2018; 10(10): 50-56.

23.   Reddy PS, Sudhakar Babu K, Kumar N. Development and validation of a stability-indicating RP-HPLC method for the simultaneous estimation of process related impurities and degradation products of rasagiline mesylate in pharmaceutical formulation. J Chromatogr Sci. 2013; 51(3): 242–9.

24.   Hammud HH, El Yazbib FA, Mahrous ME, Sonji GM, Sonji NM. Stability-indicating spectrofluorimetric and RP-HPLC methods for the determination of aspirin and dipyridamole in their combination. The Open Spectroscopy Journal. 2008; 2(1): 19–28.

25.   Sherikar O, Mehta P. Comprehensive assessment of degradation behavior of aspirin and atorvastatin singly and in combination by using a validated RP-HPLC method. Sci Pharm. 2013 Jan-Mar; 81(1): 195–210. doi: 10.3797/scipharm.1210-19.

26.   Patel SM, Patel CN, Patel VB. Stability-indicating HPLC method for simultaneous determination of aspirin and prasugrel. Indian J Pharm Sci. 2013; 75(4): 413–9.

27.   Devaka NVS, Parepalli Y, Rao VM. Stability indicating RP-HPLC method for simultaneous estimation of aspirin and prasugrel in combination capsule dosage. Res J Pharm Technol. 2021; 14(3): 1365-1369.

28.   Karnik KS, Pingle AP, Jadhav A. Development and validation of stability-indicating RP-HPLC method for simultaneous estimation of ramipril, atorvastatin calcium and aspirin in a combined capsule dosage form. World J Pharm Res. 2015; 4(7): 1612-25.

29.   Vidhi Dave, P. U. Patel. Analytical QbD Assisted RP- HPLC Method Development and Validation for Estimation of Anti-diabetic Drug Remogliflozin in Bulk and its Pharmaceutical Dosage form. Research Journal of Pharmacy and Technology. 2025; 18(7): 3244-9. doi: 10.52711/0974-360X.2025.00467

30.   Dave Vidhi, Paresh Patel. Method development and Validation of UV Spectrophotometric estimation of Remogliflozin Etabonate in bulk and its tablet dosage form. Research Journal of Pharmacy and Technology. 2021; 14(4): 2042-4. doi: 10.52711/0974-360X.2021.00362.

 

 

 

 

 

Received on 12.01.2026      Revised on 23.04.2026

Accepted on 01.07.2026      Published on 07.10.2026

Available online from October 14, 2026

Asian J. Pharm. Tech. 2026; 16(4):344-350.

DOI: 10.52711/2231-5713.2026.00048

©Asian Pharma Press All Right Reserved

 

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. Creative Commons License.